Corresponding author at: Center of Physics, University of Minho (CFUM), Campus de Gualtar, 4710-057 Braga, Portugal.
was read the article
array:24 [ "pii" => "S1888429620300054" "issn" => "18884296" "doi" => "10.1016/j.optom.2020.01.002" "estado" => "S300" "fechaPublicacion" => "2020-04-01" "aid" => "324" "copyright" => "Spanish General Council of Optometry" "copyrightAnyo" => "2020" "documento" => "article" "crossmark" => 1 "licencia" => "http://creativecommons.org/licenses/by-nc-nd/4.0/" "subdocumento" => "fla" "cita" => "J Optom. 2020;13:96-101" "abierto" => array:3 [ "ES" => true "ES2" => true "LATM" => true ] "gratuito" => true "lecturas" => array:2 [ "total" => 40 "formatos" => array:3 [ "EPUB" => 16 "HTML" => 16 "PDF" => 8 ] ] "itemSiguiente" => array:19 [ "pii" => "S1888429619300585" "issn" => "18884296" "doi" => "10.1016/j.optom.2019.07.001" "estado" => "S300" "fechaPublicacion" => "2020-04-01" "aid" => "302" "copyright" => "Spanish General Council of Optometry" "documento" => "article" "crossmark" => 1 "licencia" => "http://creativecommons.org/licenses/by-nc-nd/4.0/" "subdocumento" => "fla" "cita" => "J Optom. 2020;13:102-12" "abierto" => array:3 [ "ES" => true "ES2" => true "LATM" => true ] "gratuito" => true "lecturas" => array:2 [ "total" => 659 "formatos" => array:3 [ "EPUB" => 45 "HTML" => 453 "PDF" => 161 ] ] "en" => array:13 [ "idiomaDefecto" => true "cabecera" => "<span class="elsevierStyleTextfn">Original Article</span>" "titulo" => "The effects of two longpass filters on visual performance" "tienePdf" => "en" "tieneTextoCompleto" => "en" "tieneResumen" => array:2 [ 0 => "en" 1 => "es" ] "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "102" "paginaFinal" => "112" ] ] "titulosAlternativos" => array:1 [ "es" => array:1 [ "titulo" => "Efectos sobre el desempeño visual de dos filtros Longpass" ] ] "contieneResumen" => array:2 [ "en" => true "es" => true ] "contieneTextoCompleto" => array:1 [ "en" => true ] "contienePdf" => array:1 [ "en" => true ] "resumenGrafico" => array:2 [ "original" => 0 "multimedia" => array:8 [ "identificador" => "fig0010" "etiqueta" => "Figure 2" "tipo" => "MULTIMEDIAFIGURA" "mostrarFloat" => true "mostrarDisplay" => false "figura" => array:1 [ 0 => array:4 [ "imagen" => "gr2.jpeg" "Alto" => 1529 "Ancho" => 1508 "Tamanyo" => 170513 ] ] "detalles" => array:1 [ 0 => array:3 [ "identificador" => "at0010" "detalle" => "Figure " "rol" => "short" ] ] "descripcion" => array:1 [ "en" => "<p id="spar0010" class="elsevierStyleSimplePara elsevierViewall">Transmittance spectrum of the three types of filters (plano lenses) and spectrum of human macular pigment taken from the optical density (OD) reported in Werner et al.<a class="elsevierStyleCrossRef" href="#bib0145"><span class="elsevierStyleSup">29</span></a> (transmittance<span class="elsevierStyleHsp" style=""></span>=<span class="elsevierStyleHsp" style=""></span>10<span class="elsevierStyleSup">−OD</span>). Inset: Measured emission spectrum of the white LED lamps used as glare source to measure BCVA<span class="elsevierStyleInf">glare</span>.</p>" ] ] ] "autores" => array:1 [ 0 => array:2 [ "autoresLista" => "Federica Cozza, Matteo Monzio Compagnoni, Chiara Airoldi, Chiara Braga, Gabriele Nigrotti, Natalia Vlasak, Silvano Larcher, Fabrizio Zeri, Silvia Tavazzi" "autores" => array:9 [ 0 => array:2 [ "nombre" => "Federica" "apellidos" => "Cozza" ] 1 => array:2 [ "nombre" => "Matteo Monzio" "apellidos" => "Compagnoni" ] 2 => array:2 [ "nombre" => "Chiara" "apellidos" => "Airoldi" ] 3 => array:2 [ "nombre" => "Chiara" "apellidos" => "Braga" ] 4 => array:2 [ "nombre" => "Gabriele" "apellidos" => "Nigrotti" ] 5 => array:2 [ "nombre" => "Natalia" "apellidos" => "Vlasak" ] 6 => array:2 [ "nombre" => "Silvano" "apellidos" => "Larcher" ] 7 => array:2 [ "nombre" => "Fabrizio" "apellidos" => "Zeri" ] 8 => array:2 [ "nombre" => "Silvia" "apellidos" => "Tavazzi" ] ] ] ] ] "idiomaDefecto" => "en" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S1888429619300585?idApp=UINPBA00004D" "url" => "/18884296/0000001300000002/v2_202004291705/S1888429619300585/v2_202004291705/en/main.assets" ] "itemAnterior" => array:19 [ "pii" => "S1888429619301086" "issn" => "18884296" "doi" => "10.1016/j.optom.2019.12.003" "estado" => "S300" "fechaPublicacion" => "2020-04-01" "aid" => "317" "copyright" => "Spanish General Council of Optometry" "documento" => "article" "crossmark" => 1 "licencia" => "http://creativecommons.org/licenses/by-nc-nd/4.0/" "subdocumento" => "fla" "cita" => "J Optom. 2020;13:88-95" "abierto" => array:3 [ "ES" => true "ES2" => true "LATM" => true ] "gratuito" => true "lecturas" => array:2 [ "total" => 76 "formatos" => array:3 [ "EPUB" => 10 "HTML" => 40 "PDF" => 26 ] ] "en" => array:12 [ "idiomaDefecto" => true "cabecera" => "<span class="elsevierStyleTextfn">Original Article</span>" "titulo" => "Competencies and training needs of the Portuguese optometrists - a national inquiry" "tienePdf" => "en" "tieneTextoCompleto" => "en" "tieneResumen" => array:2 [ 0 => "en" 1 => "es" ] "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "88" "paginaFinal" => "95" ] ] "titulosAlternativos" => array:1 [ "es" => array:1 [ "titulo" => "Competencias y necesidades de formación de los Optometristas portugueses: encuesta a nivel nacional" ] ] "contieneResumen" => array:2 [ "en" => true "es" => true ] "contieneTextoCompleto" => array:1 [ "en" => true ] "contienePdf" => array:1 [ "en" => true ] "autores" => array:1 [ 0 => array:2 [ "autoresLista" => "Vera Lúcia Alves Carneiro, Jorge Jorge" "autores" => array:2 [ 0 => array:2 [ "nombre" => "Vera Lúcia Alves" "apellidos" => "Carneiro" ] 1 => array:2 [ "nombre" => "Jorge" "apellidos" => "Jorge" ] ] ] ] ] "idiomaDefecto" => "en" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S1888429619301086?idApp=UINPBA00004D" "url" => "/18884296/0000001300000002/v2_202004291705/S1888429619301086/v2_202004291705/en/main.assets" ] "en" => array:19 [ "idiomaDefecto" => true "cabecera" => "<span class="elsevierStyleTextfn">Original Article</span>" "titulo" => "Contrast sensitivity function with soft contact lens wear" "tieneTextoCompleto" => true "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "96" "paginaFinal" => "101" ] ] "autores" => array:1 [ 0 => array:4 [ "autoresLista" => "Kishor Sapkota, Sandra Franco, Madalena Lira" "autores" => array:3 [ 0 => array:4 [ "nombre" => "Kishor" "apellidos" => "Sapkota" "email" => array:1 [ 0 => "kishorsapkota@gmail.com" ] "referencia" => array:1 [ 0 => array:2 [ "etiqueta" => "*" "identificador" => "cor0005" ] ] ] 1 => array:2 [ "nombre" => "Sandra" "apellidos" => "Franco" ] 2 => array:2 [ "nombre" => "Madalena" "apellidos" => "Lira" ] ] "afiliaciones" => array:1 [ 0 => array:2 [ "entidad" => "Center of Physics, University of Minho, Braga, Portugal" "identificador" => "aff0005" ] ] "correspondencia" => array:1 [ 0 => array:3 [ "identificador" => "cor0005" "etiqueta" => "⁎" "correspondencia" => "Corresponding author at: Center of Physics, University of Minho (CFUM), Campus de Gualtar, 4710-057 Braga, Portugal." ] ] ] ] "titulosAlternativos" => array:1 [ "es" => array:1 [ "titulo" => "Función de sensibilidad al contraste con el uso de lentes de contacto blandas" ] ] "resumenGrafico" => array:2 [ "original" => 0 "multimedia" => array:8 [ "identificador" => "fig0010" "etiqueta" => "Figure 2" "tipo" => "MULTIMEDIAFIGURA" "mostrarFloat" => true "mostrarDisplay" => false "figura" => array:1 [ 0 => array:4 [ "imagen" => "gr2.jpeg" "Alto" => 1456 "Ancho" => 2925 "Tamanyo" => 260249 ] ] "detalles" => array:1 [ 0 => array:3 [ "identificador" => "at0010" "detalle" => "Figure " "rol" => "short" ] ] "descripcion" => array:1 [ "en" => "<p id="spar0010" class="elsevierStyleSimplePara elsevierViewall">Graph showing baseline and final contrast sensitivity function with different spatial frequencies with contact lenses of different materials.</p>" ] ] ] "textoCompleto" => "<span class="elsevierStyleSections"><span id="sec0005" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0065">Introduction</span><p id="par0005" class="elsevierStylePara elsevierViewall">Visual threshold to determine the smallest difference in contrast between the visible and invisible is the threshold contrast, the reciprocal of which provides contrast sensitivity.<a class="elsevierStyleCrossRef" href="#bib0005"><span class="elsevierStyleSup">1</span></a> Generally, sinusoidal gratings, which contain a gradual change from highest luminance to lowest luminance and vice-versa, are used to determine the visual contrast threshold. This is measured with different spatial frequencies and contrasts, so it measures the real-world visual function unlike the visual acuity measurement. Visual acuity only indicates the visual performance on high contrast, and generally it is measured in a 100% contrast target. It does not stand as a complete tool to represent visual performance because contrast greatly varies in the real-world visual requirements and a wide range of targets have about 1% of contrast. In some conditions, contrast sensitivity may be significantly reduced even if visual acuity remains normal.<a class="elsevierStyleCrossRef" href="#bib0005"><span class="elsevierStyleSup">1</span></a></p><p id="par0010" class="elsevierStylePara elsevierViewall">Many researchers included contrast sensitivity tests to determine the visual performance with different types of contact lenses (CL). Some have assessed contrast sensitivity as the function of different spatial frequencies, which is contrast sensitivity function (CSF),<a class="elsevierStyleCrossRefs" href="#bib0010"><span class="elsevierStyleSup">2–4</span></a> while others have measured visual acuity with high and low contrast visual acuity charts.<a class="elsevierStyleCrossRefs" href="#bib0025"><span class="elsevierStyleSup">5,6</span></a> However, low contrast visual charts reflect the slope of higher spatial frequency level alone.<a class="elsevierStyleCrossRef" href="#bib0035"><span class="elsevierStyleSup">7</span></a> Some of the previous studies found no difference in the CSF in subjects wearing spectacles and CL.<a class="elsevierStyleCrossRef" href="#bib0030"><span class="elsevierStyleSup">6</span></a> However, Ortiz et al. found lower CSF with cosmetic as well as iris tinted soft CL when compared to no correction.<a class="elsevierStyleCrossRef" href="#bib0040"><span class="elsevierStyleSup">8</span></a> Porish showed that the CSF can be improved in athletes with sport-tinted CL.<a class="elsevierStyleCrossRef" href="#bib0045"><span class="elsevierStyleSup">9</span></a> However, the improvement was too small to affect the performance of these athletes.</p><p id="par0015" class="elsevierStylePara elsevierViewall">Currently, with the high need to constantly perform tasks that require continuous observation of objects with varying degrees of contrast, and not only objects easily visible with high contrast, it becomes relevant to assess the CSF. As the CSF is positively correlated with vision-related quality of life, it is important to learn whether current CL affect contrast sensitivity.<a class="elsevierStyleCrossRefs" href="#bib0050"><span class="elsevierStyleSup">10,11</span></a> As far as the authors know, none of the previous studies determined the effect of contemporary CL wear on the CSF. The aim of this study was to investigate the effect of three months of soft CL wear on the CSF. The CSF with CL (baseline) was compared with spectacles and after three months of CL wear. The effect of lens materials, wearing modality, and gender on the CSF was also assessed.</p></span><span id="sec0010" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0070">Material and methods</span><p id="par0020" class="elsevierStylePara elsevierViewall">Ninety-four eyes of 47 healthy neophyte myopic subjects between 18 and 40 years of age with no ocular pathology were included in this longitudinal clinical trial. All the subjects had best corrected visual acuity equal or better than 6/6 in each eye. Subjects with astigmatism higher than 0.75 dioptre (D) and history of CL wear were excluded. A consent form was signed after detailed information was provided to the subjects. This study followed the tenets of the Declaration of Helsinki and was reviewed and approved by the University of Minho's Ethics Subcommittee for Life and Health Sciences. The sample size was calculated to warrant 80% statistical power with 0.05 significant level to detect the difference in LogCS by 0.15 between two conditions: with spectacles and CL at baseline; and with CL at baseline and after a period of three months of wear.</p><p id="par0025" class="elsevierStylePara elsevierViewall">Preliminary examination including slit-lamp bio-microscopy and both objective and subjective refraction was performed on each subject. Visual acuity was measured with spectacles using Snellen self-illuminated chart. CSF was measured with CSV-1000 (VectorVision, Greenvile, OH).<a class="elsevierStyleCrossRefs" href="#bib0015"><span class="elsevierStyleSup">3,12,13</span></a> This is one of the commercially available contrast sensitivity measurement tools with good reliability which applied sinusoidal gratings.<a class="elsevierStyleCrossRef" href="#bib0070"><span class="elsevierStyleSup">14</span></a> It uses an subjective method by forced-choice detection and measures the contrast sensitivity in four levels of spatial frequencies: 3, 6, 12 and 18 cycles per degree (cpd).<a class="elsevierStyleCrossRef" href="#bib0005"><span class="elsevierStyleSup">1</span></a> Each set of spatial frequency contains 17 patches with a diameter of 3.8<span class="elsevierStyleHsp" style=""></span>cm or 0.87 degrees. The first patch with highest contrast vertical sinusoidal gratings is used for explanation while the other 8 pairs of patches, numbered 1 to 8, are used for testing. The contrast of the 1st to 3rd patch decreases in 0.17 log unit steps while, from the 3rd to the 8th, it decreases in 0.15 log unit steps. The chart is retro-illuminated with an 85<span class="elsevierStyleHsp" style=""></span>cd/m<span class="elsevierStyleSup">2</span> fluorescent light which can be controlled with a remote control. Subjects were seated two and a half meters away from the chart. CSF was measured in each eye separately with their habitual spectacles. Contrast sensitivity value of the last correct response was documented. As sensitivity is the inverse of contrast values, the log unit was used, and therefore, higher log values indicate better sensitivity.<a class="elsevierStyleCrossRef" href="#bib0075"><span class="elsevierStyleSup">15</span></a> Each sinusoidal grating patch contains a bar with brightest luminance and darkest luminance, and the thickness of the bar depends on the spatial frequency of the gratings, e.g. for 3 cpd it is wider in comparison to that of 18 cpd. Thus,<elsevierMultimedia ident="eq0005"></elsevierMultimedia></p><p id="par0030" class="elsevierStylePara elsevierViewall">Schirmer's test, keratometry and biomicroscopic examination were also performed on each subject. One eye was fitted with a daily disposable lens (Nelfilcon A or Stenofilcon A or Nesofilcon A) and the other was fitted with a monthly disposable lens (Lotrafilcon B or Comfilcon A or Balafilcon A) in a contralateral manner. Only monofocal spherical CL were used in this study. Details on the CL are presented in <a class="elsevierStyleCrossRef" href="#tbl0005">Table 1</a>. Lens fitting was evaluated, and should any unacceptable fitting be found due to lens parameters, another lens was fitted from the study lens group. CSF was measured again after 30<span class="elsevierStyleHsp" style=""></span>min of CL wear. OPTIFREE® Puremoist® multipurpose disinfecting solution (Polyquad 0.001% and Aldox 0.0006%, Alcon Laboratories, TX) was provided for the care of the monthly disposable lenses. Subjects were instructed to come after three months of CL wear for follow-up evaluation and subjects were again evaluated including the CSF assessment.</p><elsevierMultimedia ident="tbl0005"></elsevierMultimedia><p id="par0035" class="elsevierStylePara elsevierViewall">Data were analysed with Statistical Software for Social Sciences (SPSS 22, IBM Corp., Armonk, NY). Kolmogorov-Smirnov test was applied to analyse the distribution of the variables; parametric tests were used to test normally distributed variables and non-parametric tests were applied to others. A repeated measures ANOVA was used to compare the CSF values in three different situations (with spectacles and with CL during baseline visit and with CL on final visit) as well as to detect the effect of gender on it. Association of changes in the CSF according to lens wearing modality (daily disposable vs monthly disposable) and type of lenses (hydrogel vs silicone hydrogel) was assessed by applying Mann-Whitney test. Correlation of the CSF with lens thickness, oxygen permeability and water content was determined by applying Spearman's rho test. P values less than 0.05 were considered as statistically significant.</p></span><span id="sec0015" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0075">Results</span><p id="par0040" class="elsevierStylePara elsevierViewall">Ninety-four eyes of 47 subjects with a mean age of 24.3<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>4.1 years were included in this study. Among these, 66.0% (31) were women. The mean refractive error was −1.86<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>1.54<span class="elsevierStyleHsp" style=""></span>D with a range of −0.75 to −5.50<span class="elsevierStyleHsp" style=""></span>D. Lotrafilcon B was worn in 16 eyes, Nelfilcon A on 16 eyes, Comfilcon A on 15 eyes, Stenofilcon A on 15 eyes, Balafilcon A on 16 eyes and Nesofilcon A on 16 eyes. Subjects used the CL for 11.8<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>1.8<span class="elsevierStyleHsp" style=""></span>h per day.</p><p id="par0045" class="elsevierStylePara elsevierViewall"><a class="elsevierStyleCrossRef" href="#tbl0010">Table 2</a> shows the values of the CSF with their habitual spectacles (before starting to wear CL), after 30<span class="elsevierStyleHsp" style=""></span>min of CL use on the first visit, and after a period of three months CL wear. Repeated measures of ANOVA shows that there is no difference in the CSF values with spatial frequency of 18 cpd (F(2, 174)<span class="elsevierStyleHsp" style=""></span>=<span class="elsevierStyleHsp" style=""></span>2–196, p<span class="elsevierStyleHsp" style=""></span>=<span class="elsevierStyleHsp" style=""></span>0.114) but there is a statistically significant difference in CSF with spatial frequencies of 3 cpd (F(1.754, 152.606)<span class="elsevierStyleHsp" style=""></span>=<span class="elsevierStyleHsp" style=""></span>12.729, p<span class="elsevierStyleHsp" style=""></span><<span class="elsevierStyleHsp" style=""></span>0.001), 6 cpd (F(1.832, 159.419)<span class="elsevierStyleHsp" style=""></span>=<span class="elsevierStyleHsp" style=""></span>14.141, p<span class="elsevierStyleHsp" style=""></span><<span class="elsevierStyleHsp" style=""></span>0.001) and 12 cpd (F(2, 174)<span class="elsevierStyleHsp" style=""></span>=<span class="elsevierStyleHsp" style=""></span>5.001, p<span class="elsevierStyleHsp" style=""></span>=<span class="elsevierStyleHsp" style=""></span>0.008). Pairwise comparison shows that baseline CSF with spectacles was less than that with baseline CSF with CL and final CSF with CL with spatial frequencies of 3, 6 and 12 cpd (p<span class="elsevierStyleHsp" style=""></span><<span class="elsevierStyleHsp" style=""></span>0.05). However, there was no significant difference between baseline CSF values with CL and final CSF values with CL with spatial frequencies of 3, 6 and 12 cpd (p<span class="elsevierStyleHsp" style=""></span>><span class="elsevierStyleHsp" style=""></span>0.05). In average, baseline CSF with CL was 0.07 higher than baseline CSF with spectacles.</p><elsevierMultimedia ident="tbl0010"></elsevierMultimedia><p id="par0050" class="elsevierStylePara elsevierViewall">As shown in <a class="elsevierStyleCrossRef" href="#fig0005">Fig. 1</a>, the CSF was higher at medium level of spatial frequency when compared to lower or higher spatial frequencies with spectacles as well as with CL during baseline and after the three-month period.</p><elsevierMultimedia ident="fig0005"></elsevierMultimedia><p id="par0055" class="elsevierStylePara elsevierViewall">There were no statistically significant differences between CSF values obtained in men and women neither with spectacles nor with CL (p<span class="elsevierStyleHsp" style=""></span>><span class="elsevierStyleHsp" style=""></span>0.05). <a class="elsevierStyleCrossRef" href="#tbl0015">Table 3</a> presents the changes in the CSF for each spatial frequency for the different lens materials after a period of three months of lens wear. There was no association of lens wearing modality with changes in the CSF values. It was similar with daily and monthly disposable lenses (p<span class="elsevierStyleHsp" style=""></span>><span class="elsevierStyleHsp" style=""></span>0.05). The CSF values were similar with silicone hydrogel lenses and hydrogel lenses (p<span class="elsevierStyleHsp" style=""></span>><span class="elsevierStyleHsp" style=""></span>0.05). Also, no significant correlation was obtained between the changes in the CSF with water content (r<span class="elsevierStyleHsp" style=""></span><<span class="elsevierStyleHsp" style=""></span>0.121, p<span class="elsevierStyleHsp" style=""></span>><span class="elsevierStyleHsp" style=""></span>0.05), oxygen permeability (r<span class="elsevierStyleHsp" style=""></span><<span class="elsevierStyleHsp" style=""></span>0.145, p<span class="elsevierStyleHsp" style=""></span>><span class="elsevierStyleHsp" style=""></span>0.05) or lens thickness (r<span class="elsevierStyleHsp" style=""></span><<span class="elsevierStyleHsp" style=""></span>0.144, p<span class="elsevierStyleHsp" style=""></span>><span class="elsevierStyleHsp" style=""></span>0.05).</p><elsevierMultimedia ident="tbl0015"></elsevierMultimedia><p id="par0060" class="elsevierStylePara elsevierViewall"><a class="elsevierStyleCrossRef" href="#fig0010">Fig. 2</a> shows the CSF for the different lens materials at baseline and at the final follow up visit. It can be observed that different materials apparently behaved differently. For example, with lotrafilcon B lens wear, the CSF increased at 3, 6 and 12 cpd, but decreased at 18 cpd, while with comfilcon A lens wear, the CSF increased in 3, 12 and 18 cpd, but decreased at 6 cpd after three months of lens wear. However, all of these differences were considered not statistically significant (p<span class="elsevierStyleHsp" style=""></span>><span class="elsevierStyleHsp" style=""></span>0.05). The difference in the CSF was not correlated with the refractive power of the lenses (r<span class="elsevierStyleHsp" style=""></span><<span class="elsevierStyleHsp" style=""></span>0.164, p<span class="elsevierStyleHsp" style=""></span>><span class="elsevierStyleHsp" style=""></span>0.05).</p><elsevierMultimedia ident="fig0010"></elsevierMultimedia></span><span id="sec0020" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0080">Discussion</span><p id="par0065" class="elsevierStylePara elsevierViewall">This study measured the effect of soft CL wear in the CSF, by comparing the scores obtained with spectacles and after a period of three months of lens wear. The effect of lens materials, wearing modality, and gender was also assessed. Significantly higher CSF was found with CL in comparison to the CSF with spectacles on the first examination for all the spatial frequencies except for the spatial frequency of 18 cpd. The lower the spatial frequency, the greater was the difference. Similar to our findings, Dalcoll et al. found an increase in the CSF with soft CL.<a class="elsevierStyleCrossRef" href="#bib0080"><span class="elsevierStyleSup">16</span></a> The CSF is a product of both neural and optical factors.<a class="elsevierStyleCrossRef" href="#bib0005"><span class="elsevierStyleSup">1</span></a> Aberration and glare affect the quality of the image, so the higher CSF with CL when compared to spectacles, may be due to the smaller asymmetric aberrations with soft CL.<a class="elsevierStyleCrossRef" href="#bib0085"><span class="elsevierStyleSup">17</span></a> Charman reported that incorrect refractive error correction reduces the CSF in high spatial frequency.<a class="elsevierStyleCrossRef" href="#bib0090"><span class="elsevierStyleSup">18</span></a> So, in the current study, no difference in the CSF with spectacles and CL in high spatial frequency of 18 cpd may be due to uncorrected astigmatism with spherical CL. Furthermore, the difference in the CSF with spectacles and with CL during the baseline visit was inferior to 0.14 Log units in all the spatial frequencies, so this difference may not be clinically significant.<a class="elsevierStyleCrossRef" href="#bib0095"><span class="elsevierStyleSup">19</span></a></p><p id="par0070" class="elsevierStylePara elsevierViewall">Contrary to the current study, a couple of previous studies found no difference in the CSF with spectacles and with soft CL wear.<a class="elsevierStyleCrossRefs" href="#bib0100"><span class="elsevierStyleSup">20,21</span></a> Gray suggested that changes in corneal physiology due to CL wear may reduce the CSF.<a class="elsevierStyleCrossRefs" href="#bib0110"><span class="elsevierStyleSup">22,23</span></a> However, in the current study, the baseline CSF was measured with CL within half an hour of lens wear. So, within this short period, no changes in corneal physiology are expected.</p><p id="par0075" class="elsevierStylePara elsevierViewall">Another important finding of this study is that three months of soft CL wear did not change the CSF. Soni et al. suggested that CL with higher thicknesses and low oxygen transmissibility may reduce the CSF by inducing corneal edema.<a class="elsevierStyleCrossRef" href="#bib0035"><span class="elsevierStyleSup">7</span></a> However, in the current study, CL were worn in a daily wear modality and the central thickness of the lenses was not more than 0.10<span class="elsevierStyleHsp" style=""></span>mm. The oxygen transmissibility of the CL used in this study was enough to avoid corneal edema on open eye condition.<a class="elsevierStyleCrossRef" href="#bib0120"><span class="elsevierStyleSup">24</span></a> Lira et al. found that CL power impacts oxygen transmissibility as the central thickness and the peripheral thickness of the CL differ significantly, especially in high power lenses.<a class="elsevierStyleCrossRef" href="#bib0125"><span class="elsevierStyleSup">25</span></a> However, low power CL (mean −1.86<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>1.54<span class="elsevierStyleHsp" style=""></span>D) were used in this work, so, it is not expected to find lower Dk/t values than those recommended for daily wear. Supporting our findings, Grey found no changes in the CSF with six months of soft CL wear.<a class="elsevierStyleCrossRef" href="#bib0115"><span class="elsevierStyleSup">23</span></a> In his six-sample size study, he concluded that the CSF initially decreases with soft CL wear but it rapidly recovers to a normal state within few hours. In another study, he found a reduction in the CSF with soft CL after few hours of wear when compared to the initial CSF with no correction.<a class="elsevierStyleCrossRef" href="#bib0110"><span class="elsevierStyleSup">22</span></a></p><p id="par0080" class="elsevierStylePara elsevierViewall">As shown in <a class="elsevierStyleCrossRef" href="#tbl0015">Table 3</a> and <a class="elsevierStyleCrossRef" href="#fig0010">Fig. 2</a>, CSF seems to vary with lens materials. There was a smaller difference in CSF on lower spatial frequency when compared to the CSF on higher spatial frequencies, and this variation was highly perceivable after three months of CL wear. However, this variation was not statistically significant. Moreover, in this study, the CSF was similar with daily disposable versus monthly disposable lenses and silicone lenses versus hydrogel lenses. Contrary to the present findings, Belda-Salmeron found that the CSF depends on the lens materials as well as lens design and manufacturing methods.<a class="elsevierStyleCrossRef" href="#bib0030"><span class="elsevierStyleSup">6</span></a> They reported severe reduction in the CSF with thicker lenses than thinner lenses and a better CSF with lathe-cut lenses as opposed to spectacles or cast-moulded lenses was found. However, in the current study, there was no significant correlation between changes in the CSF and centre thickness. This may be due to the fact that, a small range of centre thickness of the CL was used in the current study. Gupta et al. compared the CSF with two types of CLs, Purevision multifocal and Purevision single vision lenses, and found no differences in the CSF.<a class="elsevierStyleCrossRef" href="#bib0130"><span class="elsevierStyleSup">26</span></a> Similarly, Fernandes et al. found no significant difference in the CSF with multifocal and monovision CL in presbyopic subjects.<a class="elsevierStyleCrossRef" href="#bib0025"><span class="elsevierStyleSup">5</span></a></p><p id="par0085" class="elsevierStylePara elsevierViewall">This study used the CSV-1000 for contrast sensitivity measurement. Some of the studies found lower reliability of the CSV-1000 in CS measurement.<a class="elsevierStyleCrossRef" href="#bib0135"><span class="elsevierStyleSup">27</span></a> However, the same test was used during all the visits in this longitudinal study and the same examiner measured all the data. It was reported that reliability increases if performed by the same examiner.<a class="elsevierStyleCrossRef" href="#bib0135"><span class="elsevierStyleSup">27</span></a> One limitation of the study is that the CSF was measured with habitual spectacles of the subjects on the first day, and the power of the spectacles in some of the subjects might not be accurate at that time.</p><p id="par0090" class="elsevierStylePara elsevierViewall">Thus, from this study, it can be concluded that CSF is higher with soft CL when compared to the CSF with spectacles. No significant difference was found in the CSF with CL between baseline and after 3 months of lens wear. The CSF with CL does not relate to the lens materials, wearing modality and gender of the subjects. In the future, it would be interesting to explore the effect of toric and multifocal CL wear on the CSF.</p></span><span id="sec0025" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0085">Conflict of interest</span><p id="par0095" class="elsevierStylePara elsevierViewall">The authors have no conflicts of interest to declare.</p></span><span id="sec0030" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0090">Financial support</span><p id="par0100" class="elsevierStylePara elsevierViewall">This work was supported by the <span class="elsevierStyleGrantSponsor" id="gs0005">Portuguese Foundation for Science and Technology (FCT)</span> within the framework of the Strategic Funding <span class="elsevierStyleGrantNumber" refid="gs0005">UID/FIS/04650/2019</span>.</p></span></span>" "textoCompletoSecciones" => array:1 [ "secciones" => array:11 [ 0 => array:3 [ "identificador" => "xres1330543" "titulo" => "Abstract" "secciones" => array:4 [ 0 => array:2 [ "identificador" => "abst0005" "titulo" => "Purposes" ] 1 => array:2 [ "identificador" => "abst0010" "titulo" => "Methods" ] 2 => array:2 [ "identificador" => "abst0015" "titulo" => "Results" ] 3 => array:2 [ "identificador" => "abst0020" "titulo" => "Conclusion" ] ] ] 1 => array:2 [ "identificador" => "xpalclavsec1225917" "titulo" => "Keywords" ] 2 => array:3 [ "identificador" => "xres1330542" "titulo" => "Resumen" "secciones" => array:4 [ 0 => array:2 [ "identificador" => "abst0025" "titulo" => "Objetivos" ] 1 => array:2 [ "identificador" => "abst0030" "titulo" => "Métodos" ] 2 => array:2 [ "identificador" => "abst0035" "titulo" => "Resultados" ] 3 => array:2 [ "identificador" => "abst0040" "titulo" => "Conclusión" ] ] ] 3 => array:2 [ "identificador" => "xpalclavsec1225918" "titulo" => "Palabras clave" ] 4 => array:2 [ "identificador" => "sec0005" "titulo" => "Introduction" ] 5 => array:2 [ "identificador" => "sec0010" "titulo" => "Material and methods" ] 6 => array:2 [ "identificador" => "sec0015" "titulo" => "Results" ] 7 => array:2 [ "identificador" => "sec0020" "titulo" => "Discussion" ] 8 => array:2 [ "identificador" => "sec0025" "titulo" => "Conflict of interest" ] 9 => array:2 [ "identificador" => "sec0030" "titulo" => "Financial support" ] 10 => array:1 [ "titulo" => "References" ] ] ] "pdfFichero" => "main.pdf" "tienePdf" => true "fechaRecibido" => "2019-05-26" "fechaAceptado" => "2020-01-08" "PalabrasClave" => array:2 [ "en" => array:1 [ 0 => array:4 [ "clase" => "keyword" "titulo" => "Keywords" "identificador" => "xpalclavsec1225917" "palabras" => array:4 [ 0 => "Contrast sensitivity function" 1 => "Soft contact lens" 2 => "Spatial frequency" 3 => "Spectacles wear" ] ] ] "es" => array:1 [ 0 => array:4 [ "clase" => "keyword" "titulo" => "Palabras clave" "identificador" => "xpalclavsec1225918" "palabras" => array:4 [ 0 => "Función de sensibilidad al contraste" 1 => "Lentillas blandas" 2 => "Frecuencia espacial" 3 => "Uso de gafas" ] ] ] ] "tieneResumen" => true "resumen" => array:2 [ "en" => array:3 [ "titulo" => "Abstract" "resumen" => "<span id="abst0005" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0010">Purposes</span><p id="spar0035" class="elsevierStyleSimplePara elsevierViewall">To compare contrast sensitivity function (CSF) with soft contact lens (SCL) and spectacles wear. To investigate the effect of a three-month period of SCL wear on CSF.</p></span> <span id="abst0010" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0015">Methods</span><p id="spar0040" class="elsevierStyleSimplePara elsevierViewall">Forty-seven myopic subjects with no history of contact lens (CL) wear were included in this longitudinal prospective study. CSF was measured with spectacles using the CSV-1000 (VectorVision, Greenvile, OH). Subsequently, subjects were fitted with a daily disposable lens (Nelfilcon-A, Stenofilcon-A or Nesofilcon-A) in one eye and a monthly disposable lens (Lotrafilcon-B, Comfilcon-A or Balafilcon-A) in the other eye and wore the same type of CLs for three months. CSF was measured again on the same day and after three months wearing CLs. Differences in CSF with spectacles and CLs on baseline and changes to CSF after three months of CLs wear were assessed. The effect of lens materials and wearing modality on CSF change was also investigated.</p></span> <span id="abst0015" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0020">Results</span><p id="spar0045" class="elsevierStyleSimplePara elsevierViewall">CSF was higher with CLs in comparison to the values with spectacles for spatial frequencies of 3, 6 and 12 cycles per degree (cpd) (p<span class="elsevierStyleHsp" style=""></span><<span class="elsevierStyleHsp" style=""></span>0.05) while there was no difference for spatial frequency of 18 cpd (p<span class="elsevierStyleHsp" style=""></span>=<span class="elsevierStyleHsp" style=""></span>0.114). No significant difference was found in the CSF with CLs between baseline and after three months of lens wear (p<span class="elsevierStyleHsp" style=""></span>><span class="elsevierStyleHsp" style=""></span>0.05). There was no difference in CSF between hydrogel and silicone CLs as well as when comparing daily with monthly wear CLs (p<span class="elsevierStyleHsp" style=""></span>><span class="elsevierStyleHsp" style=""></span>0.05).</p></span> <span id="abst0020" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0025">Conclusion</span><p id="spar0050" class="elsevierStyleSimplePara elsevierViewall">CSF is better with CLs than with spectacles. CSF values with CL are similar between baseline and after 3 months of lens wear.</p></span>" "secciones" => array:4 [ 0 => array:2 [ "identificador" => "abst0005" "titulo" => "Purposes" ] 1 => array:2 [ "identificador" => "abst0010" "titulo" => "Methods" ] 2 => array:2 [ "identificador" => "abst0015" "titulo" => "Results" ] 3 => array:2 [ "identificador" => "abst0020" "titulo" => "Conclusion" ] ] ] "es" => array:3 [ "titulo" => "Resumen" "resumen" => "<span id="abst0025" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0035">Objetivos</span><p id="spar0055" class="elsevierStyleSimplePara elsevierViewall">Comparar la función de sensibilidad al contraste (CSF) con el uso de lentillas blandas y gafas. Investigar el efecto en la CSF de un periodo de uso de lentillas blandas de tres meses.</p></span> <span id="abst0030" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0040">Métodos</span><p id="spar0060" class="elsevierStyleSimplePara elsevierViewall">En este estudio longitudinal prospectivo incluimos a cuarenta y siete sujetos miopes sin antecedentes de uso de lentillas. La CSF se midió con gafas, utilizando el sistema CSV-1000 (VectorVision, Greenvile, OH). A continuación, se proporcionaron a los sujetos lentillas diarias desechables (Nelfilcon-A, Stenofilcon-A o Nesofilcon-A) en un ojo, y lentillas mensuales desechables (Lotrafilcon-B, Comfilcon-A or Balafilcon-A) en el otro ojo, utilizándose el mismo tipo de lentillas durante tres meses. Se volvió a medir la CSF el mismo día, y transcurridos tres meses de uso de lentillas. Se evaluaron las diferencias en cuanto a CSF con gafas y lentillas al inicio, y los cambios de CSF transcurridos tres meses de uso de lentillas. También se investigó el efecto en el cambio de CSF de las modalidades de las lentillas y la modalidad de uso.</p></span> <span id="abst0035" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0045">Resultados</span><p id="spar0065" class="elsevierStyleSimplePara elsevierViewall">La CSF fue más alta con el uso de lentillas, en comparación con el uso de gafas para las frecuencias espaciales de 3, 6 y 12 ciclos por grado (cpg) (p<span class="elsevierStyleHsp" style=""></span><<span class="elsevierStyleHsp" style=""></span>0,05), mientras que no se produjo diferencia para la frecuencia espacial de 18 cpg (p<span class="elsevierStyleHsp" style=""></span>=<span class="elsevierStyleHsp" style=""></span>0,114). No se encontró diferencia significativa de CSF entre el valor basal y transcurridos tres meses de uso de lentillas (p<span class="elsevierStyleHsp" style=""></span>><span class="elsevierStyleHsp" style=""></span>0,05). No se encontró diferencia de CSF entre las lentillas de hidrogel y silicona, ni al comparar el uso de lentillas diarias y mensuales (p<span class="elsevierStyleHsp" style=""></span>><span class="elsevierStyleHsp" style=""></span>0,05).</p></span> <span id="abst0040" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0050">Conclusión</span><p id="spar0070" class="elsevierStyleSimplePara elsevierViewall">La CSF es mejor con lentillas que con gafas. Los valores de CSF con el uso de lentillas son similares entre el valor basal y transcurridos tres meses de uso de lentillas.</p></span>" "secciones" => array:4 [ 0 => array:2 [ "identificador" => "abst0025" "titulo" => "Objetivos" ] 1 => array:2 [ "identificador" => "abst0030" "titulo" => "Métodos" ] 2 => array:2 [ "identificador" => "abst0035" "titulo" => "Resultados" ] 3 => array:2 [ "identificador" => "abst0040" "titulo" => "Conclusión" ] ] ] ] "multimedia" => array:6 [ 0 => array:8 [ "identificador" => "fig0005" "etiqueta" => "Figure 1" "tipo" => "MULTIMEDIAFIGURA" "mostrarFloat" => true "mostrarDisplay" => false "figura" => array:1 [ 0 => array:4 [ "imagen" => "gr1.jpeg" "Alto" => 823 "Ancho" => 1532 "Tamanyo" => 81336 ] ] "detalles" => array:1 [ 0 => array:3 [ "identificador" => "at0005" "detalle" => "Figure " "rol" => "short" ] ] "descripcion" => array:1 [ "en" => "<p id="spar0005" class="elsevierStyleSimplePara elsevierViewall">Graph showing contrast sensitivity function with different spatial frequencies.</p>" ] ] 1 => array:8 [ "identificador" => "fig0010" "etiqueta" => "Figure 2" "tipo" => "MULTIMEDIAFIGURA" "mostrarFloat" => true "mostrarDisplay" => false "figura" => array:1 [ 0 => array:4 [ "imagen" => "gr2.jpeg" "Alto" => 1456 "Ancho" => 2925 "Tamanyo" => 260249 ] ] "detalles" => array:1 [ 0 => array:3 [ "identificador" => "at0010" "detalle" => "Figure " "rol" => "short" ] ] "descripcion" => array:1 [ "en" => "<p id="spar0010" class="elsevierStyleSimplePara elsevierViewall">Graph showing baseline and final contrast sensitivity function with different spatial frequencies with contact lenses of different materials.</p>" ] ] 2 => array:8 [ "identificador" => "tbl0005" "etiqueta" => "Table 1" "tipo" => "MULTIMEDIATABLA" "mostrarFloat" => true "mostrarDisplay" => false "detalles" => array:1 [ 0 => array:3 [ "identificador" => "at0015" "detalle" => "Table " "rol" => "short" ] ] "tabla" => array:1 [ "tablatextoimagen" => array:1 [ 0 => array:2 [ "tabla" => array:1 [ 0 => """ <table border="0" frame="\n \t\t\t\t\tvoid\n \t\t\t\t" class=""><thead title="thead"><tr title="table-row"><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black"> \t\t\t\t\t\t\n \t\t\t\t\t\t</th><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black">Lotrafilcon B \t\t\t\t\t\t\n \t\t\t\t\t\t</th><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black">Comfilcon A \t\t\t\t\t\t\n \t\t\t\t\t\t</th><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black">Balafilcon A \t\t\t\t\t\t\n \t\t\t\t\t\t</th><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black">Stenofilcon A \t\t\t\t\t\t\n \t\t\t\t\t\t</th><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black">Nelfilcon A \t\t\t\t\t\t\n \t\t\t\t\t\t</th><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black">Nesofilcon A \t\t\t\t\t\t\n \t\t\t\t\t\t</th></tr></thead><tbody title="tbody"><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Company \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Alcon \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Cooper Vision \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Bausch & Lomb \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Cooper Vision \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Alcon \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Bausch & Lomb \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Brand name \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">AirOptix® Aqua<span class="elsevierStyleSup">TM</span> \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Biofinity<span class="elsevierStyleSup">TM</span> \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Purevision2<span class="elsevierStyleSup">TM</span> \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">MyDay<span class="elsevierStyleSup">TM</span> \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Dailies® AquaComfort Plus® \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Biotrue<span class="elsevierStyleSup">TM</span> ONEday \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Water content (%) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">34 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">48 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">36 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">54 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">69 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">78 \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Thickness (mm) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0.08 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0.08 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0.07 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0.08 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0.10 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0.1 \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Base curve/ diameter (mm) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">8.6/14.2 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">8.7/14.5 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">8.6/14 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">8.4/14.2 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">8.7/14 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">8.6/14.2 \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Oxygen Permeability (barrer)m \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">110 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">128 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">91 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">80 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">26 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">42 \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Modulus (MPa) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">1.2 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0.75 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">1.1-1.25 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0.4 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0.89 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0.49 \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Transmissibility (barrer/cm) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">137.5 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">160 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">130 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">100 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">26 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">42 \t\t\t\t\t\t\n \t\t\t\t</td></tr></tbody></table> """ ] "imagenFichero" => array:1 [ 0 => "xTab2280282.png" ] ] ] ] "descripcion" => array:1 [ "en" => "<p id="spar0015" class="elsevierStyleSimplePara elsevierViewall">Characteristics of the lenses used in the study. Nelfilcon A and nesofilcon A are hydrogel lenses while others are silicone hydrogel lenses.</p>" ] ] 3 => array:8 [ "identificador" => "tbl0010" "etiqueta" => "Table 2" "tipo" => "MULTIMEDIATABLA" "mostrarFloat" => true "mostrarDisplay" => false "detalles" => array:1 [ 0 => array:3 [ "identificador" => "at0020" "detalle" => "Table " "rol" => "short" ] ] "tabla" => array:2 [ "tablatextoimagen" => array:1 [ 0 => array:2 [ "tabla" => array:1 [ 0 => """ <table border="0" frame="\n \t\t\t\t\tvoid\n \t\t\t\t" class=""><thead title="thead"><tr title="table-row"><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black">Spatial frequency (cpd) \t\t\t\t\t\t\n \t\t\t\t\t\t</th><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black">Baseline with spectacles \t\t\t\t\t\t\n \t\t\t\t\t\t</th><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black">Baseline with CL \t\t\t\t\t\t\n \t\t\t\t\t\t</th><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black">p<a class="elsevierStyleCrossRef" href="#tblfn0005"><span class="elsevierStyleSup">a</span></a> \t\t\t\t\t\t\n \t\t\t\t\t\t</th><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black">Final with CL \t\t\t\t\t\t\n \t\t\t\t\t\t</th><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black">p<a class="elsevierStyleCrossRef" href="#tblfn0010"><span class="elsevierStyleSup">b</span></a> \t\t\t\t\t\t\n \t\t\t\t\t\t</th></tr></thead><tbody title="tbody"><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">3 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">1.58<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>0.20 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">1.66<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>0.16 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0.001 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">1.67<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>0.14 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0.502 \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">6 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">1.76<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>0.23 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">1.86<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>0.20 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0.000 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">1.88<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>0.19 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0.316 \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">12 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">1.44<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>0.26 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">1.53<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>0.24 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0.004 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">1.52<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>0.25 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0.875 \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">18 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">1.03<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>0.28 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">1.08<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>0.23 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0.114 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">1.09<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>0.26 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0.687 \t\t\t\t\t\t\n \t\t\t\t</td></tr></tbody></table> """ ] "imagenFichero" => array:1 [ 0 => "xTab2280281.png" ] ] ] "notaPie" => array:2 [ 0 => array:3 [ "identificador" => "tblfn0005" "etiqueta" => "a" "nota" => "<p class="elsevierStyleNotepara" id="npar0005">Comparison between CL and spectacles on baseline visit (day 1).</p>" ] 1 => array:3 [ "identificador" => "tblfn0010" "etiqueta" => "b" "nota" => "<p class="elsevierStyleNotepara" id="npar0010">Comparison between baseline with CL and with CL after three months [CL: contact lenses].</p>" ] ] ] "descripcion" => array:1 [ "en" => "<p id="spar0020" class="elsevierStyleSimplePara elsevierViewall">Contrast sensitivity function (in Log Units) with spectacles and with contact lenses on the first day and with contact lenses on the final day.</p>" ] ] 4 => array:8 [ "identificador" => "tbl0015" "etiqueta" => "Table 3" "tipo" => "MULTIMEDIATABLA" "mostrarFloat" => true "mostrarDisplay" => false "detalles" => array:1 [ 0 => array:3 [ "identificador" => "at0025" "detalle" => "Table " "rol" => "short" ] ] "tabla" => array:2 [ "leyenda" => "<p id="spar0030" class="elsevierStyleSimplePara elsevierViewall">Mean values<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>standard deviations are followed by p values in bracket.</p>" "tablatextoimagen" => array:1 [ 0 => array:2 [ "tabla" => array:1 [ 0 => """ <table border="0" frame="\n \t\t\t\t\tvoid\n \t\t\t\t" class=""><thead title="thead"><tr title="table-row"><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black"> \t\t\t\t\t\t\n \t\t\t\t\t\t</th><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black">3 cpd \t\t\t\t\t\t\n \t\t\t\t\t\t</th><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black">6 cpd \t\t\t\t\t\t\n \t\t\t\t\t\t</th><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black">12 cpd \t\t\t\t\t\t\n \t\t\t\t\t\t</th><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black">18 cpd \t\t\t\t\t\t\n \t\t\t\t\t\t</th></tr></thead><tbody title="tbody"><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Lotrafilcon B \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0.04<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>0.17 [0.464] \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0.08<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>0.22 [0.217] \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0.07<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>0.40 [0.608] \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">−0.02<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>0.31 [0.805] \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Comfilcon A \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0.04<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>0.09 [0.052] \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">−0.01<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>0.18 [0.320] \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0.05<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>0.26 [0.506] \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0.003<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>0.24 [0.758] \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Balafilcon A \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">−0.01<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>0.15 [0.464] \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0.001<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>0.17 [0.916] \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">−0.13<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>0.27 [0.053] \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0.02<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>0.27 [0.959] \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Nelfilcon A \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">−0.02<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>0.19 [0.465] \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0.05<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>0.22 [0.422] \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0.03<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>0.33 [0.527] \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0.07<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>0.29 [0.318] \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Stenofilcon A \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0.02<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>0.10 [0.330] \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0.03<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>0.17 [0.354] \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0.01<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>0.13 [0.892] \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">−0.04<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>0.18 [0.473] \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Nesofilcon A \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0.03<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>0.18 [0.549] \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">−0.01<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>0.12 [0.863] \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">−0.07<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>0.33 [0.717] \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0.04<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>0.28 [0.474] \t\t\t\t\t\t\n \t\t\t\t</td></tr></tbody></table> """ ] "imagenFichero" => array:1 [ 0 => "xTab2280280.png" ] ] ] ] "descripcion" => array:1 [ "en" => "<p id="spar0025" class="elsevierStyleSimplePara elsevierViewall">Changes in contrast sensitivity function (in Log Units) by three months of soft contact lens wear with different lens materials.</p>" ] ] 5 => array:5 [ "identificador" => "eq0005" "tipo" => "MULTIMEDIAFORMULA" "mostrarFloat" => false "mostrarDisplay" => true "Formula" => array:5 [ "Matematica" => "Contrast threshold = Luminance maximum-Luminance minimumLuminance maximum+Luminance minimum" "Fichero" => "STRIPIN_si1.jpeg" "Tamanyo" => 7021 "Alto" => 55 "Ancho" => 324 ] ] ] "bibliografia" => array:2 [ "titulo" => "References" "seccion" => array:1 [ 0 => array:2 [ "identificador" => "bibs0005" "bibliografiaReferencia" => array:27 [ 0 => array:3 [ "identificador" => "bib0005" "etiqueta" => "1" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Measuring contrast sensitivity" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:2 [ 0 => "D.G. Pelli" 1 => "P. Bex" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/j.visres.2013.04.015" "Revista" => array:6 [ "tituloSerie" => "Vision Res" "fecha" => "2013" "volumen" => "90" "paginaInicial" => "10" "paginaFinal" => "14" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/23643905" "web" => "Medline" ] ] ] ] ] ] ] ] 1 => array:3 [ "identificador" => "bib0010" "etiqueta" => "2" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Contrast sensitivity assessment of soft contact lens wearers" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:1 [ 0 => "S.T. Briggs" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:5 [ "tituloSerie" => "Int Contact Lens Clin" "fecha" => "1998" "volumen" => "25" "paginaInicial" => "99" "paginaFinal" => "102" ] ] ] ] ] ] 2 => array:3 [ "identificador" => "bib0015" "etiqueta" => "3" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Contrast Sensitivity in Strabologic Functional Test" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:1 [ 0 => "L. Dorn" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:5 [ "tituloSerie" => "Acta Clin Croat" "fecha" => "2008" "volumen" => "47" "paginaInicial" => "15" "paginaFinal" => "20" ] ] ] ] ] ] 3 => array:3 [ "identificador" => "bib0020" "etiqueta" => "4" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Enhancement of contrast sensitivity and losses of chromatic discrimination with tinted lenses" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:3 [ 0 => "M.D. de Fez" 1 => "M.J. Luque" 2 => "V. Viqueira" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1097/00006324-200209000-00010" "Revista" => array:6 [ "tituloSerie" => "Optom Vis Sci" "fecha" => "2002" "volumen" => "79" "paginaInicial" => "590" "paginaFinal" => "597" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/12322929" "web" => "Medline" ] ] ] ] ] ] ] ] 4 => array:3 [ "identificador" => "bib0025" "etiqueta" => "5" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Adaptation to multifocal and monovision contact lens correction" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:5 [ 0 => "P.R.B. Fernandes" 1 => "H.I.F. Neves" 2 => "D.P. Lopes-Ferreira" 3 => "J.M.M. Jorge" 4 => "J.M. González-Meijome" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1097/OPX.0b013e318282951b" "Revista" => array:6 [ "tituloSerie" => "Optom Vis Sci" "fecha" => "2013" "volumen" => "90" "paginaInicial" => "228" "paginaFinal" => "235" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/23376896" "web" => "Medline" ] ] ] ] ] ] ] ] 5 => array:3 [ "identificador" => "bib0030" "etiqueta" => "6" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Diurnal variations in visual performance for disposable contact lenses" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:5 [ 0 => "L. Belda-Salmerón" 1 => "T. Ferrer-Blasco" 2 => "C. Albarrán-Diego" 3 => "D. Madrid-Costa" 4 => "R. Montés-Micó" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1097/OPX.0b013e318299088f" "Revista" => array:6 [ "tituloSerie" => "Optom Vis Sci" "fecha" => "2013" "volumen" => "90" "paginaInicial" => "682" "paginaFinal" => "690" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/23770656" "web" => "Medline" ] ] ] ] ] ] ] ] 6 => array:3 [ "identificador" => "bib0035" "etiqueta" => "7" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Is binocular contrast sensitivity at distance compromised with multifocal soft contact lenses used to correct presbyopia?" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:3 [ 0 => "P.S. Soni" 1 => "R. Patel" 2 => "R.S. Carlson" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1097/00006324-200307000-00012" "Revista" => array:6 [ "tituloSerie" => "Optom Vis Sci" "fecha" => "2003" "volumen" => "80" "paginaInicial" => "505" "paginaFinal" => "514" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/12858086" "web" => "Medline" ] ] ] ] ] ] ] ] 7 => array:3 [ "identificador" => "bib0040" "etiqueta" => "8" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Optical Quality and Vision with Iris-Coloring Soft Contact Lenses" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:2 [ 0 => "C. Ortiz" 1 => "R. Jimenez" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1097/OPX.0000000000000212" "Revista" => array:6 [ "tituloSerie" => "Optom Vis Sci" "fecha" => "2014" "volumen" => "91" "paginaInicial" => "564" "paginaFinal" => "569" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/24681832" "web" => "Medline" ] ] ] ] ] ] ] ] 8 => array:3 [ "identificador" => "bib0045" "etiqueta" => "9" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Football players’ contrast sensitivity comparison when wearing amber sport-tinted or clear contact lenses" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:1 [ 0 => "E. Porisch" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/j.optm.2006.11.014" "Revista" => array:6 [ "tituloSerie" => "Optometry" "fecha" => "2007" "volumen" => "78" "paginaInicial" => "232" "paginaFinal" => "235" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/17478341" "web" => "Medline" ] ] ] ] ] ] ] ] 9 => array:3 [ "identificador" => "bib0050" "etiqueta" => "10" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Comparison of vision- related quality of life in primary open-angle glaucoma and dry-type age-related macular degeneration" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:3 [ 0 => "S.K. Ugurlu" 1 => "A.E.K. Altundal" 2 => "M.A. Ekin" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1038/eye.2016.219" "Revista" => array:6 [ "tituloSerie" => "Eye" "fecha" => "2017" "volumen" => "31" "paginaInicial" => "395" "paginaFinal" => "405" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/27813519" "web" => "Medline" ] ] ] ] ] ] ] ] 10 => array:3 [ "identificador" => "bib0055" "etiqueta" => "11" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Visual acuity and contrast sensitivity are two important factors affecting vision-related quality of life in advanced age-related macular degeneration" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:5 [ 0 => "M. Roh" 1 => "A. Selivanova" 2 => "H.J. Shin" 3 => "J.W. Miller" 4 => "Jackson M. Lou" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:5 [ "tituloSerie" => "PLoS One" "fecha" => "2018" "volumen" => "13" "paginaInicial" => "1" "paginaFinal" => "12" ] ] ] ] ] ] 11 => array:3 [ "identificador" => "bib0060" "etiqueta" => "12" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Age-related change in contrast sensitivity among Australian male adults: Florey Adult Male Ageing Study" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:4 [ 0 => "D.I.T. Sia" 1 => "S. Martin" 2 => "G. Wittert" 3 => "R.J. Casson" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1111/j.1755-3768.2011.02379.x" "Revista" => array:6 [ "tituloSerie" => "Acta Ophthalmol" "fecha" => "2013" "volumen" => "91" "paginaInicial" => "312" "paginaFinal" => "317" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/22429692" "web" => "Medline" ] ] ] ] ] ] ] ] 12 => array:3 [ "identificador" => "bib0065" "etiqueta" => "13" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Comparison of the VCTS-6500 and the CSV-1000 tests for visual contrast sensitivity testing" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:5 [ 0 => "S. Franco" 1 => "A.C. Silva" 2 => "A.S. Carvalho" 3 => "A.S. Macedo" 4 => "M. Lira" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/j.neuro.2010.06.004" "Revista" => array:6 [ "tituloSerie" => "Neurotoxicology" "fecha" => "2010" "volumen" => "31" "paginaInicial" => "758" "paginaFinal" => "761" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/20600292" "web" => "Medline" ] ] ] ] ] ] ] ] 13 => array:3 [ "identificador" => "bib0070" "etiqueta" => "14" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Test-retest reliability of the CSV-1000 contrast test and its relationship to glaucoma therapy" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:2 [ 0 => "G.N. Pomerance" 1 => "D.W. Evans" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:5 [ "tituloSerie" => "Investig Ophthalmol Vis Sci" "fecha" => "1994" "volumen" => "35" "paginaInicial" => "3357" "paginaFinal" => "3361" ] ] ] ] ] ] 14 => array:3 [ "identificador" => "bib0075" "etiqueta" => "15" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Application of Fourier analysis to the visibility of gratings" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:2 [ 0 => "F.W. Campbell" 1 => "J.G. Robson" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1113/jphysiol.1968.sp008574" "Revista" => array:6 [ "tituloSerie" => "J Physiol" "fecha" => "1968" "volumen" => "197" "paginaInicial" => "551" "paginaFinal" => "566" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/5666169" "web" => "Medline" ] ] ] ] ] ] ] ] 15 => array:3 [ "identificador" => "bib0080" "etiqueta" => "16" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Evaluation of optical performance of soft contact lenses in myopic correction" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:6 [ 0 => "M.W. Dalcoll" 1 => "M.R. Alves" 2 => "J. Barreto" 3 => "I.D.S. Yamane" 4 => "S. Bechara" 5 => "A. Mukai" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:5 [ "tituloSerie" => "Arq Bras Oftalmol" "fecha" => "2008" "volumen" => "71" "paginaInicial" => "37" "paginaFinal" => "41" ] ] ] ] ] ] 16 => array:3 [ "identificador" => "bib0085" "etiqueta" => "17" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "On-Eye Evaluation of Optical Performance of" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:3 [ 0 => "X. Hong" 1 => "N. Himebaugh" 2 => "L.N. Thibos" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1097/00006324-200112000-00009" "Revista" => array:6 [ "tituloSerie" => "Optom Vis Sci" "fecha" => "2001" "volumen" => "78" "paginaInicial" => "872" "paginaFinal" => "880" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/11780664" "web" => "Medline" ] ] ] ] ] ] ] ] 17 => array:3 [ "identificador" => "bib0090" "etiqueta" => "18" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Effect of refractive error in visual tests with sinusoidal gratings" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:1 [ 0 => "W.N. Charman" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:5 [ "tituloSerie" => "Br J Physiol Opt" "fecha" => "1979" "volumen" => "33" "paginaInicial" => "10" "paginaFinal" => "20" ] ] ] ] ] ] 18 => array:3 [ "identificador" => "bib0095" "etiqueta" => "19" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "On the statistical reliability of letter-chart visual acuity measurements" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:2 [ 0 => "A. Arditi" 1 => "R. Cagenello" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:5 [ "tituloSerie" => "Investig Ophthalmol Vis Sci" "fecha" => "1993" "volumen" => "34" "paginaInicial" => "120" "paginaFinal" => "129" ] ] ] ] ] ] 19 => array:3 [ "identificador" => "bib0100" "etiqueta" => "20" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Visual performance in myopic correction with spectacles and soft contact lenses" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:3 [ 0 => "B. Barth" 1 => "M.R. Alves" 2 => "N. Kara-José" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1590/s0004-27492008000100019" "Revista" => array:6 [ "tituloSerie" => "Arq Bras Oftalmol" "fecha" => "2008" "volumen" => "71" "paginaInicial" => "90" "paginaFinal" => "96" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/18408846" "web" => "Medline" ] ] ] ] ] ] ] ] 20 => array:3 [ "identificador" => "bib0105" "etiqueta" => "21" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Comparison of contrast sensitivity in different soft contact lenses and spectacles" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:4 [ 0 => "B.S. Wachler" 1 => "C.L. Phillips" 2 => "D.J. Schanzlin" 3 => "R.R. Krueger" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "Clao J" "fecha" => "1999" "volumen" => "25" "paginaInicial" => "48" "paginaFinal" => "51" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/10073637" "web" => "Medline" ] ] ] ] ] ] ] ] 21 => array:3 [ "identificador" => "bib0110" "etiqueta" => "22" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Changes in contrast sensitivity during the first hour of soft lens wear" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:1 [ 0 => "C.P. Grey" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1097/00006324-198609000-00002" "Revista" => array:6 [ "tituloSerie" => "Am J Optom Physiol Opt" "fecha" => "1986" "volumen" => "63" "paginaInicial" => "702" "paginaFinal" => "707" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/3777119" "web" => "Medline" ] ] ] ] ] ] ] ] 22 => array:3 [ "identificador" => "bib0115" "etiqueta" => "23" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Changes in contrast sensitivity during the first six months of soft lens wear" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:1 [ 0 => "C.P. Grey" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1097/00006324-198710000-00009" "Revista" => array:6 [ "tituloSerie" => "Am J Optom Physiol Opt" "fecha" => "1987" "volumen" => "64" "paginaInicial" => "768" "paginaFinal" => "774" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/3688180" "web" => "Medline" ] ] ] ] ] ] ] ] 23 => array:3 [ "identificador" => "bib0120" "etiqueta" => "24" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Critical oxygen levels to avoid corneal edema for daily and extended wear contact lenses" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:2 [ 0 => "B.A. Holden" 1 => "G.W. Mertz" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "Invest Ophthalmol Vis Sci" "fecha" => "1984" "volumen" => "25" "paginaInicial" => "1161" "paginaFinal" => "1167" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/6592160" "web" => "Medline" ] ] ] ] ] ] ] ] 24 => array:3 [ "identificador" => "bib0125" "etiqueta" => "25" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Importance of contact lens power and thickness in oxygen transmissibility" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:4 [ 0 => "M. Lira" 1 => "C. Pereira" 2 => "M.E.C.D. Real Oliveira" 3 => "E.M.S. Castanheira" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/j.clae.2014.12.002" "Revista" => array:6 [ "tituloSerie" => "Contact Lens Anterior Eye" "fecha" => "2015" "volumen" => "38" "paginaInicial" => "120" "paginaFinal" => "126" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/25554499" "web" => "Medline" ] ] ] ] ] ] ] ] 25 => array:3 [ "identificador" => "bib0130" "etiqueta" => "26" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Visual comparison of multifocal contact lens to monovision" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:3 [ 0 => "N. Gupta" 1 => "S.A. Naroo" 2 => "J.S. Wolffsohn" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1097/OPX.0b013e318194eb18" "Revista" => array:6 [ "tituloSerie" => "Optom Vis Sci" "fecha" => "2009" "volumen" => "86" "paginaInicial" => "E98" "paginaFinal" => "E105" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/19156009" "web" => "Medline" ] ] ] ] ] ] ] ] 26 => array:3 [ "identificador" => "bib0135" "etiqueta" => "27" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Reliability of the CSV-1000 in Adults and Children" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:3 [ 0 => "S.A. Kelly" 1 => "Y. Pang" 2 => "S. Klemencic" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1097/OPX.0b013e318264097b" "Revista" => array:6 [ "tituloSerie" => "Optom Vis Sci" "fecha" => "2012" "volumen" => "89" "paginaInicial" => "1172" "paginaFinal" => "1181" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/22797510" "web" => "Medline" ] ] ] ] ] ] ] ] ] ] ] ] ] "idiomaDefecto" => "en" "url" => "/18884296/0000001300000002/v2_202004291705/S1888429620300054/v2_202004291705/en/main.assets" "Apartado" => array:4 [ "identificador" => "3963" "tipo" => "SECCION" "en" => array:2 [ "titulo" => "Original Articles" "idiomaDefecto" => true ] "idiomaDefecto" => "en" ] "PDF" => "https://static.elsevier.es/multimedia/18884296/0000001300000002/v2_202004291705/S1888429620300054/v2_202004291705/en/main.pdf?idApp=UINPBA00004D&text.app=https://www.journalofoptometry.org/" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S1888429620300054?idApp=UINPBA00004D" ]
Year/Month | Html | Total | |
---|---|---|---|
2024 October | 38 | 34 | 72 |
2024 September | 69 | 77 | 146 |
2024 August | 85 | 52 | 137 |
2024 July | 75 | 27 | 102 |
2024 June | 81 | 57 | 138 |
2024 May | 48 | 39 | 87 |
2024 April | 53 | 44 | 97 |
2024 March | 45 | 33 | 78 |
2024 February | 43 | 59 | 102 |
2024 January | 49 | 57 | 106 |
2023 December | 48 | 41 | 89 |
2023 November | 45 | 79 | 124 |
2023 October | 49 | 69 | 118 |
2023 September | 44 | 57 | 101 |
2023 August | 36 | 46 | 82 |
2023 July | 56 | 44 | 100 |
2023 June | 31 | 47 | 78 |
2023 May | 54 | 48 | 102 |
2023 April | 34 | 33 | 67 |
2023 March | 37 | 33 | 70 |
2023 February | 50 | 34 | 84 |
2023 January | 45 | 40 | 85 |
2022 December | 67 | 54 | 121 |
2022 November | 48 | 48 | 96 |
2022 October | 71 | 42 | 113 |
2022 September | 47 | 76 | 123 |
2022 August | 46 | 34 | 80 |
2022 July | 47 | 47 | 94 |
2022 June | 43 | 32 | 75 |
2022 May | 44 | 27 | 71 |
2022 April | 41 | 36 | 77 |
2022 March | 41 | 32 | 73 |
2022 February | 41 | 36 | 77 |
2022 January | 40 | 47 | 87 |
2021 December | 51 | 51 | 102 |
2021 November | 37 | 55 | 92 |
2021 October | 41 | 58 | 99 |
2021 September | 48 | 46 | 94 |
2021 August | 37 | 45 | 82 |
2021 July | 27 | 44 | 71 |
2021 June | 29 | 39 | 68 |
2021 May | 35 | 41 | 76 |
2021 April | 258 | 355 | 613 |
2021 March | 137 | 80 | 217 |
2021 February | 59 | 40 | 99 |
2021 January | 56 | 43 | 99 |
2020 December | 84 | 42 | 126 |
2020 November | 71 | 29 | 100 |
2020 October | 47 | 34 | 81 |
2020 September | 80 | 52 | 132 |
2020 August | 218 | 60 | 278 |
2020 July | 234 | 64 | 298 |
2020 June | 202 | 62 | 264 |
2020 May | 427 | 104 | 531 |
2020 April | 183 | 64 | 247 |
2020 March | 126 | 44 | 170 |
2020 February | 44 | 25 | 69 |